You can also choose to fill in the desired characteristic impedance and leave one of the trace parameters blank. Selecting the button next to the blank field will calculate the missing parameter. Equations used to make these calculations are provided at the bottom of this page.
|
Relative Permittivity Equation: IPC-D-317A (Eq. 5.35)
The formula in the IPC document for Zo is not consistent with the
formula for the non-embedded microstrip, so it is not used here. The
formula shown was retains the square root of epsilon dependence with a
constant out front that is consistent with IPC-D-317A Eq. 5.32 for small
values of epsilon and/or large values of H1.
If H1<1.2H, the formula for the non-embedded
microstrip should be used. |
![]()
|