FCC LIMITS for Maximum Permissible Exposure (MPE)
(A) Limits for Occupational/Controlled Exposure

Frequency
Range (MHz)
Electric Field
Strength (V/m)
Magnetic Field
Strength (A/m)
Power Density
(mW/cm2)
Average Time
(minutes)
     0.3-3.0  
     3.0-30  
     30-300  
     300-1500  
     1500-100,000
          614  
          1842/f  
          61.4  
            --  
            --
         1.63  
         4.89/f  
         0.163  
            --  
            --
        (100)*  
        (900/f2)*  
         1.0  
         f/300  
         5
6
6
6
6
6
     f = frequency in MHz
    * = Plane-wave equivalent power density
 
(B) Limits for General Population/Uncontrolled Exposure
Frequency
Range (MHz)
Electric Field
Strength (V/m)
Magnetic Field
Strength (A/m)
Power Density
(mW/cm2)
Average Time
(minutes)
     0.3-1.34  
     1.34-30  
     30-300  
     300-1500  
     1500-100,000
           614 
           824/f 
           27.5 
             -- 
             --
          1.63  
          2.19/f  
          0.073  
             --  
             --
        (100)*  
        (180/f2)*  
          0.2  
          f/1500  
          1.0
            30  
            30  
            30  
            30  
            30

    f = frequency in MHz
    * = Plane-wave equivalent power density

Occupational/Controlled Limits
 
...... apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware* of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware* of the potential for exposure.

        * = Formal RF Safety Plan required

General Population/Uncontrolled Limits
 
...... apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not excercise control over their exposure.

For further information you can go directly to the FCC's web page on RF Safety: http://www.fcc.gov/oet/rfsafety

Copyright 1997-2002 EMC LAB INFO 10/06/2002